BHNCP - SKD-NF/ZP-9B DEVELOPER

  • MSDS: BHNCP
  • Manufacturer: MAGNAFLUX CORP
  • Product Name: SKD-NF/ZP-9B DEVELOPER
  • National Stock Number: 6850-01-090-8532
Product Identification

Product ID:SKD-NF/ZP-9B DEVELOPER
MSDS Date:04/17/1987
FSC:6850
NIIN:01-090-8532
MSDS Number: BHNCP

Responsible Party
MAGNAFLUX CORPORATION
7300 WEST LAWRENCE AVENUE
CHICAGO, IL 60656
US

Info Phone: 312-867-8000

Preparer: BRUCE C. GRAHAM

Cage: 37676

Contractor
ILLINOIS TOOL WORKS INC MAGNAFLUX DIV
GLENVIEW, IL 60025 US

Telephone: 847-657-5300/

Cage: 37676

Ingredients

NO INGREDIENT FOR THIS FORMULATION_INGREDIENT

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPOSURES ABOVE THE TLV CAN RESULT IN
CLUMSINESS AND POOR JUDGEMENT WITH RESUL- TING DANGER TO THE VICTIM
AND THOSE AROUND HIM MUCH LIKE INGESTING TOO MUCH AL- COHOL. IF
VICTIM UNCONSCIOUS DEATH IS PO SSIBLE DUE TO EITHER
SUFFOCATION/CARDIACARREST. AVOID FREQUENT/PROLONGED EXPOSURE TO
SKIN AS SOLVENT CAN IRRITATE SKIN.
Explanation of Carcinogenicity:DIOXANE UNDER INVESTIGATION AS A
POSSIBLE CARCINOGEN.
Effects of Overexposure:INHALATION: DIZZINESS, DROWSINESS, NAUSEA,
UNCONSCIOUSNESS AT HIGH EXPOSURE. SKIN: IRRITATES BY DISSOLVING
SKIN OILS. NOT ABSORBED THROUGH SKIN IN SIGNIFI- CANT AMOUNTS. EYE
CONTACT: IRRITATING DU E TO STRONG SOLVENT ACTION.INGESTION: LOW
SINGLE DOSE-TOXICITY IN TEST ANIMALS.
Medical Cond Aggravated by Exposure:NONE

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING GET MED
ATTN/GIVE CPR. IF BREATHING DIFF GIVE OXYGEN. SKIN: WASH OFF IN
FLOWING WATER OR SHOWER. REMOVE CONTAMINATED CLOTHES/WASH BEFORE
REUSE. USE SOOTHING LOTION. EYES: LIFT UPPER/LOWER EYELIDS/FLUSH
EYE W/STEADY/GENTLE FLOW WATER. ROLL EYEBALL ALL DIR'S
WHILEFLUSHING. INGESTION: DO NOT INDUCE VOMIT/IF
INHALED-ASPHYXIATION. GET MED ATTN.

Fire Fighting

Flash Point:NONE
Extinguishing Media:NONE
Fire Fighting Procedures:KEEP CONTAINERS COOL WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:AEROSOL CANS MAY BURST AT TEMPERATURES
OVER 130F. VAPORS PARTIALLY DECOMPOSE TO TOXIC GASES WHEN EXPOSED
TO FLAME, ARCS, OR RED HOT SURFACES.

Accidental Release

Spill Release Procedures:LESS THAN 1 QT, WIPE UP. GREATER THAN 1 QT
EVACU- ATE AREA. ENSURE THAT CLEAN UP CREW WEARS ALL PER-SONAL
SAFETY WEAR. THE NOSE IS NOT A RELIABLE GAUGE OF AIR
CONTAMINATION.

Handling

Handling and Storage Precautions:DO NOT HEAT AEROSOL CANS > 130F TO
ELIM POSSIBIL- ITY OF BURSTING/RELEASING UNWANTED VAPORS. STORE
AWAY FM HEAT SOURCES TO MIM DANGER FM EXPO TO FIRE
Other Precautions:DO NOT USE AROUND FLAME, ARCS, RED HOT SURFACES OR
LIGHTED SMOKING MATERIALS SO AS TO AVOID EXPOSURE TO PHOSGENE AND
HYDROCHLORIC ACID. DO NOT BREATHE VAPORS. IF VAPOR VICTIM
UNCONSCIOUS DEATH IS POS SIBLE DUE TO SUFFOCATION/CARDIAC ARREST.

Exposure Controls

Respiratory Protection:IN POORLY VENTILATED AREAS VAPORS ARE DENSE AND
SINK TO LOW SPOTS. THE USER SHOULD WEAR A RESPIRATOR WITH
CHEMICAL CARTRIDGE. IN CONFINED UNVENTILATED SPACES THE
INSPECTOR SHOULD WEAR A FULL MASK WITH A SEPARATE AIR SUPPLY.
Ventilation:GEN VENT MUST BE SUFF TO KEEP CONCENTRATION OF SKD-NF
VAPORSBELOW 350 PPM. BASE VENTILATION RATE ON CONSUMPTION.
Protective Gloves:WEAR NITRILE RUBBER GLOVES.
Eye Protection:WEAR FULL CLEAN GOGGLES.
Work Hygienic Practices:WASH WITH FLOWING WATER. WASH CONTAMINATED
CLOTHING BEFORE REUSE.
Supplemental Safety and Health
NK

Chemical Properties

Boiling Pt:B.P. Text:162F
Vapor Pres:230MM@100F
Vapor Density:4
pH:NEUT'L
Evaporation Rate & Reference:3 TIMES > ETHYL ALCOHOL
Solubility in Water:NEGLIGIBLE
Appearance and Odor:WHITE, MOBILE LIQUID
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:NO
POWERED ZINC AND ALUMINUM
Hazardous Decomposition Products:PHOSGENE, HYDROCHLORIC ACID. PHOSGENE
EXTREMELY TOXIC/CAN'T BE RELIABLY DETECTED BY ODOR. HYDROCHORIC
ACID ALMOST AS TOX

Disposal

Waste Disposal Methods:DISPOSE OF AS EPA HAZARDOUS WASTE #F002. MAY BE
SENT TO SOLVENT RECLAIMER. ENSURE THAT AEROSOL CANS ARE EMPTY
AND DEPRESSURIZED BEFORE DISCARD- ING, UNLESS A WASTE TREATMENT
FACILITY IS APPROVED TO ACCEPT THEM AS IS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.